About 76,500 results
Open links in new tab
  1. Introduction to Modbus and Modbus Function Codes

    Jan 30, 2023 · Introduction to Modbus and Modbus Function Codes Modbus is one of the oldest industrial communication protocols still in use today. Continue reading to find out how the protocol …

  2. Modbus: The Original Industrial Fieldbus Protocol

    Sep 2, 2025 · This article introduces Modbus, an industrial protocol that laid the foundation for fieldbus communication in industrial systems.

  3. Modbus client application | Automation & Control Engineering Forum

    Jan 9, 2024 · Open Modbus adds two other IEEE754 32 bit floating formats with its LE button which selects between Big Endian and Little Endian. Win-tech two standard FP formats correspond to the …

  4. Modbus over Ethernet | Automation & Control Engineering Forum

    Jun 25, 2008 · Modbus is a protocol. You can use Modbus protocol over Ethernet, it is then called Modbus TCP/IP. Commonly used by Schneider Electric, as Schneider bought the company Modicon, …

  5. How to find unknown Slave id on MODBUS Serial Communication

    Feb 9, 2025 · Since the sensors were connected via daisy chain, only one comm port was in use, so all the sensors used the same serial comm settings, baud rate, parity, stop bit. So what worked …

  6. Modbus RTU illegal data address - Control.com

    Sep 5, 2018 · I have 2 PLC controllers and in one controller I have Mapped variables to address 400001, 400002, 400004 and 400005 respectively and 400003 is not mapped. From Master if I try …

  7. Timeout error | Automation & Control Engineering Forum

    Feb 10, 2025 · Modbus Poll is a Modbus master simulator. If your ESP32 is indeed a master, then this won't work, as a Modbus master cannot communicate to another Modbus master.

  8. What could be causing lag in Modbus TCP/IP between Siemens PLC …

    Apr 12, 2025 · We tested the communication with a Modbus Sim and can see the lag on it too so i dont believe it is the python script. I believe its something to do with with the comms between the PLC and …

  9. Modbus Receive Timeout Error | Automation & Control Engineering …

    Nov 2, 2017 · Hi, I am new to Modbus. Right now I am trying to communicate and read registers from PM5100 Schneider Digital Meter via USB485B (USB to RS485 Converter) using ModScan32. For …

  10. Modbus Simulator Software (Master/Client) - Control.com

    Aug 25, 2025 · A while ago, I created a Modbus simulator (Master/Client) and made it available for download. If you'd like to try it out, feel free. It's available for...